A question for wineador folks out there. I've had NewAir 280-E with drawers and shelves by Forrest for about a year now and everything was working swimmingly. Then I noticed (heard) my cigar oasis was running all the time inside the wineador.
I checked my 4 bead bags and they were all dry. I wet them with distilled water and put them back. The oasis stopped running after about 15 mins and all was good.
A few days later the same thing is happening again. The oasis is running all the time and the bead bags are dry . I go through the same process all over again.
This goes on a few times then I check the drain plug and reservoir for the water and it is completely filled and leaking into the back of the NewAir 280 (no damage).
Then I monitor this problem for the next two times and the same things occur. Oasis runs all the time, beads are dry, wet beads, oasis stops running, two days later oasis is running again, beads are dry and resevoir in back is filled with water.
I'm in NJ so the humidity is OK as I have my AC on and I use 65% RH beads.
Any advice or comments is appreciated. Thanks
I checked my 4 bead bags and they were all dry. I wet them with distilled water and put them back. The oasis stopped running after about 15 mins and all was good.
A few days later the same thing is happening again. The oasis is running all the time and the bead bags are dry . I go through the same process all over again.
This goes on a few times then I check the drain plug and reservoir for the water and it is completely filled and leaking into the back of the NewAir 280 (no damage).
Then I monitor this problem for the next two times and the same things occur. Oasis runs all the time, beads are dry, wet beads, oasis stops running, two days later oasis is running again, beads are dry and resevoir in back is filled with water.
I'm in NJ so the humidity is OK as I have my AC on and I use 65% RH beads.
Any advice or comments is appreciated. Thanks